Execution ignores batch node start time and executes a batch with start time in the future (Q805)
Symptoms:
If a batch id exists in the batch node and has a start time in the future, the SIMCA®-online versions listed above fail to respect this start time and will start the real-time (normal) execution as soon as that batch id is found in the process data (as long as phase conditions are fulfilled).
Cause:
The execution logic was incorrect in regards to this.
Resolution:
Fixed in SIMCA®-online 13.2.
Workaround:
Avoid prepopulating the batch node too early. Improve the phase conditions so that those prevent the batch from starting prematurely.
More Information:
Only real-time (normal) execution of the configuration behaves as described above. Repredict execution always respect the batch start and end times of the batch node.
For more information about the SIMCA®-online server execution logic, see the SIMCA®-online Technical Guide.